Skip to content
Ungewitter

RuleModern statics

1890 against modern statics

modern.compare.kern-gsf

documentedimplementedModernUngewitter 1890 (Mohrmann)

Stated in a medieval text.

Statement

The same section judged twice. Ungewitter (elastic view): the most favourable line of thrust must keep to the kern of every joint, and the edge pressure below the allowable. Heyman (plastic view): some line of thrust must fit inside the masonry; the margin is the geometric factor of safety. The kern rule is stricter (a factor of about 3 against Heyman’s 2 for arches), so where Ungewitter accepts a design the modern check accepts it too; the reverse does not hold. For buttresses the modern check adds the fracture that the 1890 monolithic analysis leaves out.

Sources

Where implemented

@ungewitter/statics#compareArch

Tools in this area

Terms