Statement

A buttress overturns about its outer toe when the moment of the thrust exceeds that of its weight and of the vertical loads on it. The minimum depth is the one at which it just holds the thrust; the geometric factor is the actual depth over the minimum depth. The arch always pushes with at least its least thrust (if the buttress gives way, the arch settles into that state), so that is the thrust the buttress must hold. Huerta shows that the competing definitions of buttress safety (geometric, by load, by the middle third) are not equivalent; this tool shows the geometric factor beside the kern check.

Formula

λ=∑V(D−x)+G(D−xG)∑Hy,GSF=D/Dmin⁡

Sources

Where implemented

@ungewitter/statics#overturning, minimumDepth, checkButtress