Statement
Under the rule set "Ungewitter 1890, statics" the buttress is not sized by a rule of experience but by the 1890 method itself: the Table I thrust of the actual vaults, with roof, snow and wind, is traced through wall and buttress course by course, and the depth is the smallest that keeps the line of pressure within the kern and the edge pressure within the allowable at every joint. While a slider is dragged only the base joint is checked (the moment equation behind Tables 2 to 4); on release every joint is traced.
Sources
Where implemented
@ungewitter/model#sizeAbutmentDepth, staticSizing