Vault weight and thrust per square metre of plan (Table I)

statics.vault.table-i

treatiseimplementedUngewitter 1890 (Mohrmann)

Stated in a 19th-century treatise, above all the Lehrbuch of 1890.

Statement

For symmetrical, near-square quadripartite vaults, the vertical load V₀ and horizontal thrust H₀ per m² of plan, by rise group (1:8 to 5:6) and construction type, multiplied by the plan area carried by the abutment (half of one vault in a row, Fig. 366). The larger H₀ applies to small vaults, the smaller to large ones; intermediate rises are interpolated. W acts at the wall face, ⅛ to ⅓ of the rise above the springing.

Formula

V=V0A,H=H0A

Parameters

h0_span_bounds_m.max
4
h0_span_bounds_m.min
8
errata
p135-group-v-h

Sources

Where implemented

@ungewitter/statics#lookupTableI, vaultForcesTableI, tributaryArea