Skip to content
Ungewitter

RuleStatics

Wind on roofs

statics.wind.roof

treatiseimplementedUngewitter 1890 (Mohrmann)

Stated in a 19th-century treatise, above all the Lehrbuch of 1890.

Statement

Vertical wind load and horizontal wind thrust per m² of windward roof surface, by pitch, from a normal pressure of 120·sin²α (the table applies α + 10° at all pitches). The windward support may be lifted above 60°. The horizontal thrust goes to the fixed support, or for safety wholly to either side.

Formula

n=120sin2⁡(α+10∘),V=ncos⁡α,H=nsin⁡α

Modern note

The formula reproducing every table cell to ±1 kg/m², including the split between the supports, is our reconstruction.

Sources

Where implemented

@ungewitter/statics#windOnRoof, windRoofTableKg, windRoofFormulaKg

Tools in this area