RuleLab
Lab arch: modelling assumptions
lab.arch.model
Our default where the sources give a range or say nothing.
Statement
The Lab analyses a strip 1 m deep of a symmetric arch ring of uniform thickness, divided into voussoirs with radial joints and a vertical crown joint. The unit weight is 24 kN/m³, about the 2400 kg/m³ that Tables 2–4 assume for ashlar. Loads are self-weight and an optional point load at the crown. Each buttress is a plain rectangle checked course by course. Haunch backing and fill are left out, though Ungewitter backs round and pointed arches up to 1/3–1/2 of their height. Without that backing, the bare ring needs more thickness to keep its line in the kern.
Parameters
- unit_weight_kN_m3
- 24
- strip_depth_m
- 1
- voussoirs_per_half
- 12
Sources
„… es ist bei ihm aber eine gute Hintermauerung bis mindestens zu ⅓ der Höhe, besser bis etwa zur Hälfte der Höhe erforderlich.“
Where implemented
@ungewitter/statics#archRing