Skip to content
Ungewitter

RuleLab

Lab arch: modelling assumptions

lab.arch.model

assumedimplementedUngewitter 1890 (Mohrmann)

Our default where the sources give a range or say nothing.

Statement

The Lab analyses a strip 1 m deep of a symmetric arch ring of uniform thickness, divided into voussoirs with radial joints and a vertical crown joint. The unit weight is 24 kN/m³, about the 2400 kg/m³ that Tables 2–4 assume for ashlar. Loads are self-weight and an optional point load at the crown. Each buttress is a plain rectangle checked course by course. Haunch backing and fill are left out, though Ungewitter backs round and pointed arches up to 1/3–1/2 of their height. Without that backing, the bare ring needs more thickness to keep its line in the kern.

Parameters

unit_weight_kN_m3
24
strip_depth_m
1
voussoirs_per_half
12

Sources

Where implemented

@ungewitter/statics#archRing

Tools in this area

Lessons on the same pages

Terms