Skip to content
Ungewitter

RuleSection and elevation

The buttress receiving the flyers

elevation.flyer.buttress-check

treatiseimplementedUngewitter 1890 (Mohrmann)

Stated in a 19th-century treatise, above all the Lehrbuch of 1890.

Statement

The outer buttress is checked against the aisle thrust, the flyer thrust at its foot and the wind in the coping, stabilised by its own weight (a trapezoid with vertical inner face), the aisle wall, the aisle vault load, the flyer weight and the upward wind part. In the example the pressure point falls just outside the kern.

Formula

∑Wi(X−xi)=∑Hjzj,xG=a2+ab+b23(a+b)

Modern note

The buttress depth of 0.55 of the aisle width follows Fig. 912 (3.2 m for 6 m) and is our default.

Sources

Where implemented

@ungewitter/gothic#buttressCheck

Tools in this area

Terms