A rib net set out on a principal arch is checked: (1) the nodes lie on the intended surface (the sphere for domical vaults, level along the vessel for tunnel nets, the conoid of the springer for fans); (2) every piece can be struck with the principal radius (its chord is at most 2R), and no springing piece is horseshoed, else make the principal arch pointed; (3) along a straight line of ribs no node lies below the line of its neighbours, otherwise it sags inward and collapse is to be feared; (4) heights rise along every train from the springing to the crown.
Modern note
The tolerances (2 % of the crown height for the surface, none for sag) are ours; the book judges by eye.
Sources
Ungewitter 1890, p. 66 (scan), Fig. 150
„Einsturz zu befürchten“
“collapse is to be feared”
Ungewitter 1890, p. 67 (scan), Fig. 151
Where implemented