RuleOther
Geometric factor of a vault, read on its equivalent arch
rulesmodern.vault.gsf
Our default where the sources give a range or say nothing.
Statement
For each vault of the section the Studio reads Heyman’s geometric factor on an equivalent arch of the same span and rise, 1/15 of the span thick: how much thinner that arch could be before no line of thrust fits. It is an estimate resting on the assumed thickness, so it is shown as a note (a warning only if no line fits at all), never as an error; a real cross vault has thinner webs and stiffer ribs, and needs thrust network analysis for a proper factor.
Formula
Parameters
- thickness_over_span
- 0.0667
Sources
Where implemented
@ungewitter/model#vaultVerdict