Statement

For each vault of the section the Studio reads Heyman’s geometric factor on an equivalent arch of the same span and rise, 1/15 of the span thick: how much thinner that arch could be before no line of thrust fits. It is an estimate resting on the assumed thickness, so it is shown as a note (a warning only if no line fits at all), never as an error; a real cross vault has thinner webs and stiffer ribs, and needs thrust network analysis for a proper factor.

Formula

GSF=d/dmin⁡,d=s/15