RuleOther
Buttress depth by the modern criterion
rulesmodern.buttress.sizing
Our derivation from a construction or rule in the sources.
Statement
Under the rule set “Modern (Heyman)” the buttress is sized the way the rule set “Ungewitter 1890, statics” sizes it, at the same typical cuts and with the same loads (Table I vault thrust, roof, snow, wind, the flyer’s push in a basilica), but by a different criterion: the depth is the smallest at which the cracked buttress reaches its target factor in every load case, D = max(t, max over the cases of target × D_min). The least depth D_min is found by bisection on the family of wall-plus-buttress bodies whose breadth grows with the depth. Limit analysis presupposes that the masonry neither crushes nor slides, so the 1890 checks of edge pressure and sliding still apply at every joint (the kern does not); where they need more depth the buttress is deepened until they hold.
Formula
Parameters
- target_permanent
- 2
- target_storm
- 1
Sources
Where implemented
@ungewitter/model#sizeAbutmentModern, modernSizing