Skip to content
Ungewitter

RulePortals

Stepped jamb: orders and step size

portal.orders

treatiseimplementedUngewitter 1890 (Mohrmann)

Stated in a 19th-century treatise, above all the Lehrbuch of 1890.

Statement

The jamb has two parts: the door jamb proper, which carries lintel or slab, and the jamb of the arch. Most Romanesque and many early Gothic portals step outward in more or less numerous right-angled orders with a column in each re-entrant. The side ab of a step follows from ordinary ashlar sizes, because the stepped plan assumes the joints bc and bd and the arch rings have the same depth: as a rule at least 25 to 30 cm. Smaller steps would put two corners in one block. The number of orders is free; square steps give a 45° envelope.

Formula

a≥25…30 cm,xk=W2+ka,yk=r+(n−k)a

Parameters

stepMin_cm
25 – 30
rigaMeasured.orders
3
rigaMeasured.step_m
0.31

Sources

  • „Das Gewände zerfällt in zwei Teile, das eigentliche Thürgewände (g in Fig. 1288), welches den Sturz oder die Platte trägt und das Gewände des Bogens“
    “The jamb falls into two parts, the door jamb proper (g in Fig. 1288), which carries the lintel or slab, and the jamb of the arch”

    Ungewitter 1892, p. 539 (scan), Fig. 1288, 1288a

  • „mithin in der Regel mindestens 25—30 cm betragen“
    “hence as a rule at least 25 to 30 cm”

    Ungewitter 1892, p. 540 (scan), Fig. 1287, 1287a

Where implemented

@ungewitter/gothic#portalLayout

Tools in this area

Lessons on the same pages