Stated in a 19th-century treatise, above all the Lehrbuch of 1890.
Statement
For choir vaults: fold the rib arch over O–A into the plan, add the rib and web thickness, and draw the tangent at the midpoint of the outer arc; where it cuts the springing line lies the buttress face. Semicircle 1/5 to 1/4 L, less for pointed arches; not applicable above a rise of 2:3. Wall and buttress thickness as in Hoffstadt (L/10).
Formula
Modern note
The closed form of the tangent construction and the default e = 0.30 m (rib plus web) are our reading of Fig. 754.
Sources
Ungewitter 1890, p. 274 (scan), Fig. 754
Where implemented