Skip to content
Ungewitter

RuleModern statics

Geometric factor of safety

modern.arch.gsf

documentedimplementedModern

Stated in a medieval text.

Statement

Heyman measures the safety of an arch by its geometry, not by stresses: the factor by which its thickness could be reduced, keeping the centre line, before no line of thrust fits any more, GSF = d / d_min. He suggests about 2 for arches. Read the same way, Ungewitter’s kern rule (the line in the middle third of every joint) asks for a factor of about 3.

Formula

GSF=d/dmin⁡,kern rule≈3

Parameters

recommended_arch
2
kern_equivalent
3

Sources

Where implemented

@ungewitter/statics#heymanArch, narrowestBand

Tools in this area

Terms