Skip to content
Ungewitter

RuleSection and elevation

How high the buttress must rise

elevation.upper-wall.buttress-height

treatiseimplementedUngewitter 1890 (Mohrmann)

Stated in a 19th-century treatise, above all the Lehrbuch of 1890.

Statement

The walling over the wall rib acts as a horizontal arch between the buttresses; its thrust line drops e = c·Q/S on the way, with c = d/3, Q the weight over one wall rib and S the top lateral force of one field. The buttress must reach at least to that point below the eaves.

Formula

e=cQ/S,c=d/3

Modern note

In the section generator Q and S are scaled from Beispiel II (half the wall above the springing; 5000 kg per 6 m bay).

Sources

  • „e zu 0,33 · 48000 : 5000 = 3,2 m. Der Punkt P, bis zu welchem mindestens der Strebepfeiler zu führen ist, würde also etwa 3 bis 3½ m unter der Traufe liegen.“
    “e = 0.33 · 48000 : 5000 = 3.2 m. The point P, up to which the buttress must at least be carried, would lie about 3 to 3½ m below the eaves.”

    Ungewitter 1892, p. 341 (scan), Fig. 839, 839a

Where implemented

@ungewitter/gothic#buttressTopDrop

Tools in this area

Terms