arch.crown-load

treatiseimplementedUngewitter 1890 (Mohrmann)

Stated in a 19th-century treatise, above all the Lehrbuch of 1890.

Statement

The more slender the pointed arch, the more it needs a load at the crown. For the equilateral arch take it at 1/7 to 1/4 of the arch's weight, for instance a heavy keystone. Much more slender arches need a crown load up to the weight of the rest of the arch and more. Without it, the line of thrust leaves the arch most easily at the intrados just under the crown. The right size is easily found by trial construction of the line of thrust.

Formula

P≈17…14Garch(R=s)

Sources

  • „Je schlanker der Bogen wird, um so wichtiger ist die Scheitellast, bei einem gleichseitigen oder 60 gradigen Spitzbogen (dem gleichseitigen Dreieck umschrieben) wird sie zweckmässig schon zu ⅐ bis ¼ des Bogengewichtes angenommen werden …“
    “The more slender the arch becomes, the more important the crown load; for an equilateral or 60-degree pointed arch (circumscribing the equilateral triangle) it is expediently taken at 1/7 to 1/4 of the arch's weight …”

    Ungewitter 1890, p. 54 (scan), Fig. 127

  • „Die angemessene Grösse der Scheitellast ist sehr leicht durch versuchsweise Konstruktion der Stützlinie zu ermitteln.“

    Ungewitter 1890, p. 55 (scan)

Where implemented

@ungewitter/statics#analyseArch