RuleStatics
TNA vault model: surface, loads and envelope
statics.tna.vault-model
Our default where the sources give a range or say nothing.
Statement
Ribs and boundary arches are circular arcs reaching a common crown (the arcs of a gothic layout with the free crown method). Each course follows the middle part of its boundary arch’s profile, as in a barrel cut by the diagonals, set on the rib heights at its ends and lifted to the ridge at its crown. Loads come from the geometry: web thickness times unit weight over the true surface area, the rib section along the ribs and boundary arches, solid backing in the pockets up to one third of the rise (the book’s lower bound for round and pointed vaults), and 1.25 cm of plaster. The thrust surface must lie between the soffit and the soffit plus the vertical web thickness; at the ribs it may use the rib’s depth below; within the backing it may rise to the backing level. The thrust enters the springers at a common height between the springing and the backing level.
Parameters
- backing_fraction_of_rise
- 0.3333
- plaster_kN_m2
- 0.2125
- vertical_thickness_cap
- 4
- unit_weights_kg_m3.porous_brick
- 1,250
- unit_weights_kg_m3.brick
- 1,600
- unit_weights_kg_m3.sandstone
- 2,000
- unit_weights_kg_m3.rubble
- 2,400
- unit_weights_kg_m3.fill
- 1,600
Sources
„sie gilt für symmetrisch gebildete Kreuzgewölbe von quadratischem oder schwach rechteckigem Grundriss mit geringer oder kleiner Ueberhöhung“
„… es ist bei ihm aber eine gute Hintermauerung bis mindestens zu ⅓ der Höhe, besser bis etwa zur Hälfte der Höhe erforderlich.“
Where implemented
@ungewitter/statics#courseNetwork, tableIBuild