RulePiers
Crushing hardly governs
pier.area.crushing
Stated in a 19th-century treatise, above all the Lehrbuch of 1890.
Statement
A stone pier could rise 80 m before reaching 20 kg/cm²; a vault field of 50 m² (25 000 kg) needs only 1250 cm², about 35 × 35 cm. Piers are sized by the springing, slenderness and thrust, not by crushing.
Formula
Sources
„25000 : 20 = 1250 qcm oder etwa 35 cm mal 35 cm“
“25000 : 20 = 1250 cm², or about 35 cm by 35 cm”
Where implemented
@ungewitter/gothic#pierPlan