Skip to content
Ungewitter

RuleModern statics

Estimated range of a vault’s thrust

modern.vault.thrust-range

assumedimplementedModern

Our default where the sources give a range or say nothing.

Statement

An estimate, not a method of the literature. The vault’s vertical load on one abutment comes from Table I; its range of thrust is taken from an equivalent arch of the same span and rise, thickness 1/15 of the span, whose least and greatest H/V are scaled by that load. A real cross vault can find more lines in its webs, so its range is wider; a full analysis needs thrust network analysis (phase 6).

Formula

Hv∈[κmin⁡,κmax⁡]⋅VTable I

Parameters

thickness_over_span
0.0667

Sources

Where implemented

@ungewitter/statics#vaultThrustRange

Tools in this area

Lessons on the same pages