Skip to content
Ungewitter

RuleArches

An arch stands while a line of thrust fits

arch.stability

treatiseimplementedUngewitter 1890 (Mohrmann)

Stated in a 19th-century treatise, above all the Lehrbuch of 1890.

Statement

An arch or vault is held to be sound as long as a satisfactory line of thrust is still possible within it. If the line leaves the arch entirely and the mortar takes no tension, the arch collapses: the joints of rupture open alternately outside and inside, always on the side away from the line.

Formula

|ej|<dj/2for every joint j

Modern note

In 1966 Heyman restated this criterion as the safe theorem of plastic analysis. That modern reading is the subject of Lesson 13 (epic 2).

Sources

  • „… überhaupt hält man einen Bogen oder ein Gewölbe noch für haltbar, so lange noch eine befriedigende Drucklinie in ihm möglich ist.“
    “… in general an arch or vault is still considered sound as long as a satisfactory line of pressure is possible within it.”

    Ungewitter 1890, p. 52 (scan), Fig. 124

  • „Würde gar die Drucklinie ganz aus dem Bogen hinaustreten, so würde, falls nicht der Mörtel Zug aushält, sicher ein Einsturz erfolgen. … Die Bruchfuge öffnet sich stets an der von der Drucklinie abgewandten Seite.“

    Ungewitter 1890, p. 53 (scan), Fig. 124c

Where implemented

@ungewitter/statics#analyseArch

Tools in this area

Lessons on the same pages

Terms