Skip to content
Ungewitter

RuleStatics

Table I recomputed by TNA

statics.tna.table-i

derivedimplementedModern

Our derivation from a construction or rule in the sources.

Statement

Each row of Table I is built as a quadripartite vault of its rise ratio (1:8, 1:3, 1:2, 2:3, 5:6) and web type (a–f), at the book’s two example spans of 4 and 8 m, with brick ribs of 12 × 25 cm (enlarged beyond a 9 m diagonal): square, as the book’s examples, and oblong with a bay length of 1.25 and 1.5 times the span. For an oblong bay the rise ratio is taken over the span in the direction of the thrust (p. 137), so the bay is set against the row of its rise over the transverse span and the thrust across the vessel is compared. The comparison is made on the ratio of thrust to weight per abutment, which does not depend on unit weights; the TNA range in kg/m² is that ratio times the book’s V₀. The book’s range counts as inside, overlapping, below or above the TNA range.

Parameters

length_ratios
1, 1.25, 1.5
length_ratio_note
the book puts no number on “slightly oblong”; 1.25 and 1.5 are our reading
thickness_search
bisection on the factor for web thickness and rib depth within [1, 4], then within [4, 16]; until wave 6 the search stopped at ×4, and four steep 8 m bays at 1 : 1.5 (Va, Vb, IVf, Vf) were reported without a network. They need ×5.5 to ×8.2. Without fill the least factor of an 8 m bay is twice that of the 4 m bay (geometric similarity: the binding element is the last course before the wall arch, whose funicular under its nearly uniform load keeps its shape whatever the load)

Sources

Where implemented

@ungewitter/statics#recomputeTableIRow

Tools in this area

Lessons on the same pages

Terms