Stated in a 19th-century treatise, above all the Lehrbuch of 1890.
Statement
Iron ties and cramps may be stressed to 700–1000 kg/cm² (bronze about half); a tie meant to take the vault thrust is sized for the whole thrust. Ties are only a conditionally reliable means.
Formula
Sources
Where implemented
@ungewitter/statics#tieRodArea