Wind on towers and spires

spire.wind

treatiseimplementedUngewitter 1890 (Mohrmann)

Stated in a 19th-century treatise, above all the Lehrbuch of 1890.

Statement

Stresses: 120 kg/m², 150 to 180 on tall roofs and walls; about 200 kg/m² is the highest observed in Europe. Overturning: at least 250 kg/m² on the face of square bodies struck normally and 200 kg/m² on the full vertical section of round and octagonal towers and spires; with 120 the stability moment must be twice the overturning moment. Shape factors: square struck on the corner 0.707, cylinder 0.785, octagonal prism 0.707. The book loads a spire with the full pressure on its triangle, acting at a third of its height.

Formula

Mk=pcbh2⋅h3≤Ms=Ga

Sources

Where implemented

@ungewitter/statics#spireOverturning, spireAnchorForce, SPIRE_WIND_KG, WIND_SHAPE_FACTOR