Skip to content
Ungewitter

RuleSection and elevation

The coping as wind strut

elevation.flyer.coping-strut

treatiseimplementedUngewitter 1890 (Mohrmann)

Stated in a 19th-century treatise, above all the Lehrbuch of 1890.

Statement

The wind on the clerestory and the nave roof, less the middle piers’ share, about 8000 kg in the example, can only be taken by the rising coping: S = W / cos α, with an upward part W·tan α; its section must be S over the allowable stress, 7 kg/cm² for brick in lime mortar.

Formula

S=W/cos⁡α,A=S/σzul

Sources

  • „sie kann nur aufgenommen werden durch die schräg ansteigende obere Abdeckung, welche überdies durch ihren hohen Anfall gegen die oberen Mauerteile den Wind da abfängt, wo er zur Geltung kommt“
    “it can only be taken by the obliquely rising upper coping, which moreover, by meeting the upper parts of the wall high up, catches the wind where it acts”

    Ungewitter 1892, p. 402 (scan)

Where implemented

@ungewitter/gothic#copingStrut

Tools in this area

Terms