Skip to content
Ungewitter

RuleTracery

Width of a light

tracery.light.width

treatiseimplementedUngewitter 1890 (Mohrmann)

Stated in a 19th-century treatise, above all the Lehrbuch of 1890.

Statement

Glass panels are usually 50–75 cm wide; a light glazed in one column of panels is 70–90 cm, at most 100 cm, wide, and with vertical storm bars about 150 cm. Lights narrower than 0.50 m or wider than 1.20 m are flagged.

Formula

0.50m≤wlight≤1.20m

Modern note

The 0.50–1.20 m band is our check on the book’s panel and light widths.

Sources

  • „Die Breite der Tafeln lässt sich der nötigen Steifigkeit wegen nicht gut über 60 bis 100 cm steigern, gewöhnlich beträgt sie nur 50—75 cm“
    “For stiffness the width of the panels cannot well be raised beyond 60 to 100 cm; usually it is only 50–75 cm”

    Ungewitter 1892, p. 488 (scan)

  • Ungewitter 1892, p. 489 (scan), Fig. 1130, 1131, 1132

Where implemented

@ungewitter/gothic#traceryLayout

Tools in this area