Skip to content
Ungewitter

RuleStatics

Sliding in a joint

statics.joint.sliding

treatiseimplementedUngewitter 1890 (Mohrmann)

Stated in a 19th-century treatise, above all the Lehrbuch of 1890.

Statement

Sliding is possible when the angle between the pressure and the joint falls below 45–60° with soft mortar, or 30–45° with hardened mortar. The safe (upper) end of each range is used.

Formula

θ=arctan⁡(D/|S|)≥60∘ (soft), 45∘ (hardened)

Parameters

soft_deg
45 – 60
hardened_deg
30 – 45

Sources

Where implemented

@ungewitter/statics#checkJoint (SLIDING_LIMIT_DEG)

Tools in this area

Terms