Skip to content
Ungewitter

RuleMouldings

Drip (Wassernase, Unterschneidung)

moulding.drip

derivedimplementedUngewitter 1890 (Mohrmann)

Our derivation from a construction or rule in the sources.

Statement

Every exterior cornice must stop water running down the wall below; the undercut makes it drop from a drip edge in front of the wall face. Under an overhanging roof edge the undercut is unnecessary. The book gives no groove dimensions; from Fig. 992 the hanging lip is 5/16 of the slope (never less than 1/4), the undercut rises about 0.14 P above the drip edge, and its deepest point stays about 0.05 P in front of the wall face, never behind it. In brick an undercut is at most one flat or rowlock course high. On a raised gable coping the drip is worked under the coping and the roofing tucks under it.

Formula

ac≥14L, ac=516L;xg≥0

Modern note

The lip limits and the wall-face condition are printed; the undercut height and throat position are measured off Fig. 992.

Sources

Where implemented

@ungewitter/gothic#ProfileLine

Tools in this area

Terms