RuleMouldings
Drip (Wassernase, Unterschneidung)
moulding.drip
Our derivation from a construction or rule in the sources.
Statement
Every exterior cornice must stop water running down the wall below; the undercut makes it drop from a drip edge in front of the wall face. Under an overhanging roof edge the undercut is unnecessary. The book gives no groove dimensions; from Fig. 992 the hanging lip is 5/16 of the slope (never less than 1/4), the undercut rises about 0.14 P above the drip edge, and its deepest point stays about 0.05 P in front of the wall face, never behind it. In brick an undercut is at most one flat or rowlock course high. On a raised gable coping the drip is worked under the coping and the roofing tucks under it.
Formula
Modern note
The lip limits and the wall-face condition are printed; the undercut height and throat position are measured off Fig. 992.
Sources
„Das Hauptgesims muss wie jedes andere Gesims ein Herablaufen des Wassers an der darunter liegenden Mauerflucht verhindern“
“The main cornice, like every other cornice, must prevent water running down the wall face below”
Ungewitter 1892, p. 438 (scan), Fig. 988, 989, 990, 991
Ungewitter 1892, p. 439 (scan), Fig. 992
Ungewitter 1892, p. 430 (scan), Fig. 950, 950a, 951
Ungewitter 1892, p. 470 (scan), Fig. 1084, 1084a
Where implemented
@ungewitter/gothic#ProfileLine