Regensburg Cathedral

Regensburg · Dom St. Peter · Regensburger Dom · Wikidata Q280268

6 measured · 3 published · 7 provisional

The chief Gothic cathedral of Bavaria, on the French pattern but with three staggered apses in place of an ambulatory, a transept that does not project, and a nave of only five bays, limited by the bounds of the cathedral precinct.

Facts

Main building campaign
1275–1525 provisionalde Wikipedia, revision 272275450Gothic rebuild begun 1275; roofed 1443/1450; work ceased c. 1525.
Plan type
Basilica, 3 vessels, with transept provisionalde Wikipedia, revision 272275450Basilican plan, three-storey nave elevation after French model.
Material
stone provisionalde Wikipedia, revision 272275450de: limestone, with some green sandstone.
Nave bays
5 provisionalde Wikipedia, revision 272275450Nave limited to five bays by immunity boundary.
Towers
West towers 105 m; spires added 1859-1869 (fr also says spires 70 m). provisionalde Wikipedia, revision 272275450
Vaults
Nave: quadripartite publishedDehio & von Bezold, Tafel 451, Fig. 1
East end
apse, no ambulatory publishedDehio & von Bezold, Tafel 451, Fig. 1Three staggered apses, no ambulatory.
Towers in plan
two west towers, one more tower provisionalde Wikipedia, revision 272275450Two west towers, finished 1859–1869; the Eselsturm on the north side; the crossing tower was begun but never finished (de).
Flying buttresses
one tier publishedDehio & von Bezold, Tafel 466, Fig. 2One flyer at the nave; the choir has buttresses with pinnacles only.

Dimensions

DimensionsValueConventionSource
Nave width14.47 m ± 0.1 mNave piers, axis to axisaxis to axismeasuredDehio & von Bezold, Tafel 451, Fig. 1measured from (1013, 2460.5) to (1439.5, 2456) px; scale 30 m = 884 px
Aisle widths11.39 m ± 0.1 mNorth aisle, pier axis to inner face of the window wallaxis to axismeasuredDehio & von Bezold, Tafel 451, Fig. 1measured from (677.5, 2350) to (1013, 2350) px; scale 30 m = 884 px
Bay length8.34 m ± 0.05 mNave pier axes over 4 bays (mean; the bays vary)axis to axismeasuredDehio & von Bezold, Tafel 451, Fig. 1measured from (1440, 1976.5) to (1440, 2959.5) px; scale 30 m = 884 px · over 4 bays
Nave vault height31.85 mconvention not statedprovisionalde Wikipedia, revision 272275450

Height of central nave (key dimensions list).

Other figures
Piers2.71 m ± 0.1 mNave pier across the shafts, transverseoverallmeasuredDehio & von Bezold, Tafel 451, Fig. 1measured from (1394.5, 2221) to (1474.5, 2221) px; scale 30 m = 884 px
Buttress depths2.58 m ± 0.1 mNorth buttress, outer face to inner face of the window walloverallmeasuredDehio & von Bezold, Tafel 451, Fig. 1measured from (601.5, 2236) to (677.5, 2236) px; scale 30 m = 884 px
Wall thicknesses0.71 m ± 0.1 mNorth aisle wall (window wall) between the buttressesoverallmeasuredDehio & von Bezold, Tafel 451, Fig. 1measured from (656.5, 2350) to (677.5, 2350) px; scale 30 m = 884 px

The design in plan

Plan of the design made from Regensburg Cathedral: quadripartite nave vaults, apse, no ambulatory.010 m
The Studio design made from the values on this page, drawn by the Studio’s own generators: cut masonry black, vault ribs dashed overhead. It is a design after the building, not a survey of it.

One bay in plan, to scale

Plan of one bay of Regensburg Cathedral: nave 14.47 m between pier axes, buttress depth 2.58 m; dashed outline of Amiens Cathedral for comparison.14.47 m2.58 m010 m
Drawn from the values above: nave piers, aisles, outer wall and buttresses of one bay. Buttress breadth is schematic. The dashed outline is Amiens Cathedral at the same scale.

As a design

The measured values as a Studio design: vessels, nave width, aisle and bay ratios, nave bays, choir ending and transept, the springings (measured, or the vault crown less a rise of 2:3 over the clear span), the piers and the material. The recorded facts above, each with its source, give the vault types (the nave quadripartite), the chevet, the towers and the tiers of flyers; the building’s date sets the period of its tracery and portals. Everything else keeps the Studio’s defaults.

Measured against the 1890 statics and the modern check

The design is sized twice at its typical nave bay: by the 1890 statics (the least depth of wall and buttress that keeps the line of pressure in the kern) and by the modern check (Heyman: the least depth with a geometric factor of 2). The depth measured on the plate is then checked with the same forces by both criteria, so all three columns are judged alike.

Measured against the 1890 statics and the modern check
QuantityBuilding, measuredUngewitter 1890, staticsModern check (Heyman)
Depth of wall and buttress2.58 m measured2.9 m2.9 m
Building ÷ this depth–0.890.89
Kern rule of 1890edge pressure too high (with wind from the left)kern left in the storm only (with wind from the left)kern left in the storm only (with wind from the left)
Geometric factor, cracked1.57 against 2: stands, small margin2.06 against 2: safe2.06 against 2: safe
Pier (1890 plan rule)2.71 m1.96 m–
Wall between the buttresses (1890 plan rule)0.71 m1.31 m–

Forces at the springing of the nave vault, 23.97 m above the floor.

Why they differ

  • The building is shallower than the statics asks: in the model the line of pressure leaves the kern of the measured depth. The modern check asks less: only that a line of thrust stays inside the masonry, which its geometric factor measures.
  • Weight set high on a flyer pier (pinnacles, statues, the upper stages) turns the resultant downward; the design carries none of it.
  • The check is drawn in one plane: one typical bay of the nave, the buttress breadth taken as a share of its depth, the wall as measured where known. Real buttresses vary along the church.

Ungewitter’s rules against this building

The rules of experience reported by Ungewitter and Mohrmann (1890, pp. 273–276) size the abutment of one vault span. Here they are applied to this building’s spans and heights and set against the buttresses measured on the plate.

In a basilica the nave vault is abutted through the flying buttresses by the whole system: aisles and outer buttress together. Ungewitter’s single-span rules were never meant for it, which is the point of the comparison.

Nave vault: span 11.76 m, springing at 24.01 m

RuleFilled inRule saysBuilding hasBuilding ÷ rule
Mohrmann, rule 5D = (0.222 · 11.76 m + 0.05 · 24.01 m) · 0.896 = 3.42 m3.42 m12.62 m3.69
HoffstadtD = 11.76 m / 10 + √2 · 11.76 m / 10 = 2.84 m2.84 m12.62 m4.44
Viollet-le-DucD = 8.17 m · (1 − cos(2 · 73.7 ° / 3)) = 2.83 m2.83 m12.62 m4.46
HaseD = 2.83 m + 0.15 m · 24.01 m / 4.5 m = 3.63 m3.63 m12.62 m3.48
Earlier editionsD = (8.17 m + 0.3 m) / cos(37.2 °) − 8.17 m = 2.46 m2.46 m12.62 m5.13

Building has: whole abutment system: aisles + buttress, from the nave pier’s face

No aisle vault height is known, so the aisle vault is not checked.

Assumptions

  • Vault rise 2/3 of the span (a low pointed arch); springing height = vault height − rise.
  • Heavy stone; no help from the walls between the buttresses.

The modern check: Heyman’s geometric factor

The rules above size a buttress by proportion. Here the measured buttress is checked by limit analysis against an estimate of the vault’s thrust: how much shallower could it be before it overturns, as one block and once cracked?

Cracked, the buttress would not hold the estimated thrust (geometric factor 0.84).

QuantityValue
Vault thrust per bay (estimate, Table I)58 kN
Height of the thrust (springing)24.01 m
Buttress depth (measured)2.58 m
Buttress breadth (assumed: half the depth)1.29 m
Thrust it holds: block | cracked103 | 34 kN
Minimum depth: block | cracked2.13 | 3.07 m
GSF on depth: block | cracked1.21 | 0.84
Fracture height24.01 m
1890: base joint, eccentricity ÷ kern1.68

Assumptions

  • Estimates: quadripartite vault, rise 2/3 of the span, Table I (mean H₀); ashlar 24 kN/m³; the thrust acts on the inner face at the springing; buttress breadth half its depth; the masonry above the springing (pinnacles) is ignored, which is conservative.
  • In a basilica the outer buttress takes the nave vault’s thrust through the flyers; the aisle vault is left out.
  • Cracked buttress after Ochsendorf (2002) and Ochsendorf, Hernando & Huerta (2004): a straight fracture from the toe, its height from the published equations (checked against both worked examples).

How the modern check works →

Plates

Public-domain plates of this building in Dehio and von Bezold’s atlas. Open them in the Heidelberg viewer or measure them with tools/plate-digitiser.

Sources

Every work this page cites, with the plates and article revisions it uses. The plates of Dehio and von Bezold are in the public domain; Wikipedia articles serve as pointers, each fixed to its revision.